Selection of patients over 75 years old for open combined surgery and endpointsof assessment of outcomes of aortic valve replacement with coronary arteriesbypass grafting: reflections on a clinical case

Authors: T.G. Nikitina, R.M. Muratov, A.A. Fadeev, N.Z. Tsitlidze, L.A. Glushko

Company:
Bakoulev National Medical Research Center for Cardiovascular Surgery, Ministry of Health of the Russian Federation, Rublevskoe shosse, 135, Moscow, 121552, Russian Federation

E-mail: Сведения доступны для зарегистрированных пользователей.

DOI: https://doi.org/10.24022/1814-6910-2018-15-4-277-285

UDC: 616.126.52-089.844:616.132.2-089.86]-053.9-089-059

Link: Clinical Physiology of Blood Circulaiton. 2018; 15 (4): 277-285

Quote as: Nikitina T.G., Muratov R.M., Fadeev A.A., Tsitlidze N.Z., Glushko L.A. Selection of patients over 75 years old for open combined surgery and endpoints of assessment of outcomes of aortic valve replacement with coronary arteries bypass grafting: reflections on a clinical case. Clinical Physiology of Circulation. 2018; 15 (4): 277–85 (in Russ.). DOI: 10.24022/1814-6910-2018-15-4-277-285

Received / Accepted:  09.06.2018/10.07.2018

Download
Full text:  

Abstract

The article says on the outcomes of conventional combined surgery in a patient aged 79, NYHA III functional class, EuroSCORE >10: aortic valve replacement (AVR) with coronary arteries bypass grafting (CABG). In 81 months after surgery, the ECHO assessment for aortic pericardial biological prosthesis – the Carpentier-Edwards PERIMOUNT was as follows: the cusps of prosthesis were flexible and quick acting; the peak/mean systolic gradients were close to 20/11 mm Hg that did not exceed postoperative values. No evidence was found for the ischemia's zones of patient's myocardium by means of myocardium scintigraphy. The cardiorespiratory exercise test has confirmed satisfactory level of the patient's physical performance. The value of peakVO2 (14.8 ml/kg/min) was as much as 82% of the required parameters. NYHA II functional class was confirmed. The normal parameters of oxygen pulse (12 ml/bpm), respiratory biomechanics and ventilation- perfusion ratio (Vd/Vt) were established. Neither ischemically significant change in the ST segment nor heart rhythm disturbances was found. In evaluating the health-related quality of patient's life – by the questionnaires of SF-36, DASI index, Minnesota's and Nottingham's Profile – the state of physical and mental health, an emotional state and the role functioning capacity of the patient were estimated as good. Appropriate patient selection is essential for successful combined open surgery for AVR and CABG in the patients of advanced age.

References

  1. Vasques F., Lucenteforte E., Paone R., Mugelli A., Biancari F. Outcome of patients aged ≥80 years undergoing combined aortic valve replacement and coronary artery bypass grafting: a systematic review and metaanalysis of 40 studies. Am. Heart J. 2012; 164: 410–8. DOI: 10.1016/j.ahj.2012.06.019
  2. Гендлин Г.Е., Тронина О.А., Мурсалимова А.И. Аортальный стеноз и артериальная гипертензия. Медицинский вестник. 2011; 10: 9–10. [Gendlin G.E., Tronina O.A., Mursalimova A.I. Aortic stenosis and hypertension. Meditsinskiy Vestnik (Medical Bulletin). 2011; 10: 9–10 (in Russ.).]
  3. Ross J. Jr, Braunwald E. Aortic stenosis. Circulation. 1968; 38 (Suppl. 1): 61–7. DOI: 10.1161/01.CIR.38.1S5.V-61
  4. Rosenhek R., Zilberszac R., Schemper M., Czerny M., Mundigler G., Graf S. et al. Natural history of very severe aortic stenosis. Circulation. 2010; 121: 151–6. DOI: 10.1161/CIRCULATIONAHA.109.894170
  5. Алекян Б.Г., Бузиашвили Ю.И., Голухова Е.З., Бокерия О.Л., Никитина Т.Г., Петросян К.В. и др. Непосредственные результаты чрескожных коронарных вмешательств у пациентов старше 80 лет с хронической ишемической болезнью сердца. Грудная и сердечно-сосудистая хирургия. 2014; 6: 14–6. [Alekyan B.G., Buziashvili Yu.I., Golukhova E.Z., Boсkeria O.L., Nikitina T.G., Petrosyan K.V. et al. Short-term results of transdermal coronary interventions at patients aged ≥80 years with chronic ischemia. Russian Journal of Thoracic and Cardiovascular Surgery. 2014; 6: 14–6 (in Russ.).]
  6. Хугаева А.А., Никитина Т.Г. Непосредственные результаты хирургического лечения клапанных пороков сердца у пациентов 75 лет и старше. Факторы риска и предикторы госпитальной летальности. Грудная и сердечно-сосудистая хирургия. 2017; 59 (4): 259–65. DOI: 10.24022/0236-2791-2017-59-4-259-265] [Khugaeva A.A., Nikitina T.G. Short-term results of surgical treatment of valve diseases at patients aged ≥75 years. Risk factors and predictors of hospital mortality. Russian Journal of Thoracic and Cardiovascular Surgery. 2017; 59 (4): 259–65 (in Russ.). DOI: 10.24022/0236-2791-2017-59-4-259-265]
  7. Zingone B., Gatti G., Rauber E., Tiziani P., Dreas L., Pappalardo A. et al. Early and late outcomes of cardiac surgery in octogenarians. Ann. Thorac. Surg. 2009; 87:
  8. Пелех Д.М., Никитина Т.Г., Фадеев А.А., Скопин И.И., Изосимова М.Г. Оценка клинического статуса пациентки с двукратным превышением индекса массы тела и выраженным протез-пациентным несоответствием через 15 лет после коррекции митрально-аортального порока механическими протезами St. Jude Medical Standard. Клиническая физиология кровообращения. 2017; 14 (3): 170–7. DOI: 10.24022/1814-6910-2017-14-3-170-177 [Pelekh D.M., Nikitina T.G., Fadeev A.A., Skopin I.I., Izosimova M.G. Clinical status assessment of a female patient with double the normal body mass index and with a severe valve prosthesis/patient mismatch 15 years after the mitral and aortic valves replacement with St. Jude Medical Standard Mechanical Prostheses. Clinical Physiology of Circulation. 2017; 14 (3): 170–7 (in Russ.). DOI: 10.24022/1814-6910-2017-14-3-170-177]
  9. Dearani J.A. Robotic heart surgery: hype or hope? J. Thorac. Cardiovasc. Surg. 2018; 155: 77–8. DOI:10.1016/j.jtcvs.2017.09.063
  10. Бокерия Л.А. Результаты научной и лечебной деятельности Национального медицинского исследовательского центра сердечно-сосудистой хирургии им. А.Н. Бакулева Минздрава РФ в 2017 году как показатель состояния и развития специальностей сердечно-сосудистого профиля. Сердечно-сосудистые заболевания. Бюллетень НЦССХ им. А.Н. Баку- лева РАМН. 2018; 19 (2): 121–266. DOI: 10.24022/1810-0694-2018-19-2-121-266 [Bockeria L.A. The results of scientific and clinical activities of Bakoulev National Medical Research Center for Cardiovascular Surgery in 2017 as an indicator of the current state and perspective development of cardiovascular specialities. Bulletin of Bakoulev Center for Cardiovascular Diseases. 2018; 19 (2): 121–266 (in Russ.). DOI: 10.24022/1810-0694-2018-19-2-121-266]
  11. Sabik J.F. Fit the operation to the patient, not the patient to the operation. J. Thorac. Cardiovasc. Surg. 2015; 150: 1393–5. DOI: 10.1016/j.jtcvs.2015.09.010
  12. Бокерия Л.А., Аронов Д.М. Российские клинические рекомендации. Коронарное шунтирование больных ишемической болезнью сердца: реабилитация и вторичная профилактика. CardioСоматика. 2016; 7 (3–4): 5–71. [Bokerya L.A., Aronov D.M. Russian clinical guidelines. CABG in patients with ischemic heart disease: rehabilitation and secondary prevention. Kardiosomatika (Cardiosomatics). 2016; 7 (3–4): 5–71 (in Russ.).]
  13. Melby S.J., Zierer A., Kaiser S.P., Guthrie T.J., Keune J.D., Schuessler R.B. et al. Aortic valve replacement in octogenarians: risk factors for early and late mortality. Ann. Thorac. Surg. 2007; 83 (5): 1651–6. DOI: 10.1016/j.athoracsur.2006.09.068
  14. Flameng W., Herregods M.C., Vercalsteren M., Herijgers P., Bogaerts K., Meuris B. Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves. Circulation. 2010; 121: 2123–9. DOI: 10.1161/CIRCULATIONAHA.109.901272
  15. McClure R.S., Narayanasamy N., Wiegerinck E., Lipsitz S., Maloney A., Byrne J.G. et al. Late outcomes for aortic valve replacement with the Carpentier- Edwards Pericardial Bioprosthesis: up to 17-year follow- up in 1,000 patients. Ann. Thorac. Surg. 2010; 89: 1410–6. DOI: 10.1016/j.athoracsur.2010.01.046
  16. Wahlers T.C., Borger M.A., Shresta M., Kocher A.A., Walther T. et al. Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patients. J. Thorac. Cardiovasc. Surg. 2014; 148: 2854–61. DOI: 10.1016/j.jtcvs. 2014.07.049
  17. Klomp W.W.J., Nierich A.P., Peelen L.M., Brandon G.J., Bruinsma B., Dambrink J.-H.E. et al. Survival and quality of life after surgical aortic valve replacement in octogenarians. J. Cardiothorac. Surg. 2016; 11: 38–44. DOI: 10.1186/s13019-016-0432-0

About Authors

  • Nikitina Tat'yana Georgievna, Dr. Med. Sc., Professor, Head of Department of Cardiology of Acquired Heart Defects; orcid.org/0000-0003-4656-6299
  • Muratov Ravil' Muratovich, Dr. Med. Sc., Professor, Head of Department of Emergency Surgery of Acquired Heart Defects; orcid.org/0000-0003-3321-9028
  • Fadeev Aleksandr Alekseevich, Cand. Tech. Sc., Head of Laboratory for the Use of Polymers in Cardiovascular Surgery; orcid.org/0000-0001-5358-0027
  • Tsitlidze Nino Zurabovna, Cardiologist; orcid.org/0000-0002-4479-4688
  • Glushko Lyudmila Alеksandrovna, Cand. Med. Sc., Head of Group of Pulmonary Samples and Gas Exchange Monitoring, Cardiologist; orcid.org/0000-0002-6532-7261

 If you found mistakes, select text and press Alt+A